RCC - Column, SLA, Beams and Cover

Explain what are Column, SLA, Beams and Cover?

Questions by cool.aruna

Showing Answers 1 - 27 of 27 Answers

feroze ali

  • Aug 6th, 2008
 

Column is a vertical compressive member which takes vertical loads from the slabs, beams, etc.

Beamsare horizantal tensile members that takes shear forces and b.m's from the slabs.

Cover is the spacing between the c/c of the reinforcement provided in tensile zone to the topedge of that member.

  Was this answer useful?  Yes

santosh londhe

  • Apr 26th, 2014
 

1.column-40mm ,
2.footing-75mm ,
3. plinth beam - 65mm ,
4.slab-20mm ,
5. beam -25mm

  Was this answer useful?  Yes

seenu

  • Jun 26th, 2014
 

Column - 40 mm on longer dimension; 25mm on shorter dimension;
Slab - 25mm maximum in case of residential or commercial buildings; 40mm in case of deck slab in flyover or grade separator which has a higher depth of 600mm;
Beams - 25mm on all sides;

  Was this answer useful?  Yes

naveed

  • Jul 1st, 2014
 

footing:50mm
column:40mm
beam:25mm
slab:20mm

  Was this answer useful?  Yes

Nirav Bhatt

  • Nov 24th, 2014
 

Referring to IS 456 Clause 26.4 for Column - 40 mm (Dia of bar >12mm) and 25 mm (Dia of bar <= 12mm). For Footing 50mm. Referring to Table 16A and design experience, normal cover for Beams 30mm, for Slab 25 mm, ribs and thin slab 20mm.

  Was this answer useful?  Yes

ch penchalaiah

  • Mar 2nd, 2015
 

Rcc desings

  Was this answer useful?  Yes

Give your answer:

If you think the above answer is not correct, Please select a reason and add your answer below.

 

Related Answered Questions

 